<LOGO>
FM Transmitter Measurement Report
Created: 2026-05-08 06-24-23
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 53 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.2 kHz 70 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 64 kHz 19216 2,9403
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,7 dBr 4,46 dBr 5,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 6:24, 8.05.2026
RT
"YleX Soi "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 64 kHz MIN: 10 kHz % above 76 kHz: 2,9403 Acquired: 2026/05/08 6.23.19 Total samples: 19216 Equivalent time: 0:16:00 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,1 dBr MIN: 2,7 dBr AVE: 4,46 dBr % above 12,2 dBr: 0,0 Last value: 4,6 dBr (2026/05/08 6.23.18) 06.10 06.12 06.14 06.16 06.18 06.20 06.22 0 2 4 6 Pm [dBr]